4 of 4 Flash Jobs in the West Midlands

Power Systems Engineer — Service Upgrades Engineering

Location
Rugby, England, United Kingdom
simulation tools including MATLAB, DigSilent PowerFactory, eTAP, PSCAD, and PSS/E; studies include short circuit, load flow, harmonic, transient, insulation co-ordination, arc flash, and protection co-ordination analysis. Author equipment specifications and technical documentation — generate main and balance-of-plant equipment specifications, functional documents, and test documentation ...

Diagnostic V&V Engineer

Hiring Organisation
Tata Technologies Europe Ltd
Location
Warwick, Warwickshire, West Midlands, United Kingdom
Employment Type
Permanent
DoIP networks . Validate Transport Layer behavior and message flow for diagnostics - related ECUs. Investigate issues related to DTCs, session handling, security unlocking, flash sequences, etc. Capture and interpret network logs to support root - cause analysis. Tools & Test Execution Execute diagnostic test cases using industry - standard tools such ...

HV Critical Systems Director

Location
Birmingham, England, United Kingdom
Undertake and review network modelling and analysis , including: Protection coordination studies Short-circuit and fault level calculations Load flow and power quality studies Arc flash hazard analysis and mitigation strategies Use and oversee studies using ETAP, Trimble, or equivalent power system analysis software . Provide technical due diligence … Proficiency in power system analysis software such as ETAP, Trimble or equivalent . Demonstrated capability in protection studies, fault analysis, load flow, and arc flash assessments . Strong understanding of resilience and redundancy architectures (N+1, 2N) and their application to critical systems. Experience with DNO interfaces , G99 compliance ...

Senior Protection Settings Engineer

Location
Stafford, England, United Kingdom
faults using sequence components. Use power system analysis software (e.g., DIgSILENT PowerFactory) for fault level studies and protection grading/selectivity reports. Conduct arc‐flash analysis using tools such as Alpi Caneco BT for LVAC 400V systems. Prepare first‐time energisation circuit switching programs and automatic reclosure switching sequence … Distribution industry. Solid understanding of protection device and scheme principle of operation. Previous use of a power system analysis and modelling software and Arc‐flash analysis software preferred. Fluent oral and written English. Ability to analyse and resolve problems. Ability to plan and execute to very tight delivery schedules. ...